PRODUCTS INDEX  ll SINGLE-LINE SYSTEMS lljOTHER PRODUCTS



DUAL – LINE SYSTEMS :

The Pump delivery & relief lines are both connected to the change – over valve. This valve system allows the two main lines to pressurize and relieve alternatively. All metering elements are piped into both main lines. The supply of lubricant to the lubrication points is ensured when both main lines have been repressurized and relived in correct sequence. An end pressure relay situated at the end of the main line senses the differential pressure between the two lines and regulates the change over. Dual Line Systems provide reliable lubrication for large and extended installations, on heavy duty plant and equipment working under adverse conditions.

Manual Pumps :

"AFMC' make manually operated pump is a basic lubricant compressor for the manually operated Two-line centralised lubrication system. Our Model Monomatic series is a semi automatic pump having an externally mounted four way self reversing valve Model No. ‘COV-2’ for supplying lubricant alternatively to the two supply lines and our Duomatic series pump has an in-built push-pull type four way flow directing valve for supplying the lubricant alternatively to the two supply lines.The pump is complete with reservoir, tell-tale rod,pressure gauge, line filter, filler connection and mounting bracket. For further details refer to the table below :

Sl.No. Model Discharge Max. Working Pressure Reservoir Capacity
01.
Duomatic 415 W
4 c.c /cycle
150 kg/cm sq
1.5 litres
02.
Duomatic 425 W
4 c.c /cycle
150 kg/cm sq
2.5 litres
03.
Duomatic 1035 P2
10 c.c/cycle
100 kg/cm sq
3.5 litres
04.
Duomatic 7535 P2
7.5 c.c/cycle
100 kg/cm sq
3.5 litres
05.
Monomatic 415 W
4 c.c /cycle
150 kg/cm sq
1.5 litres
06.
Monomatic 425 W
4 c.c /cycle
150 kg/cm sq
2.5 litres
07.
Monomatic 1035 P2
10 c.c/cycle
100 kg/cm sq
3.5 litres
08.
Monomatic 7535 P2
7.5 c.c/cycle
100 kg/cm sq
3.5 litres
 
^TOP
<PRODUCTS INDEX



Automatic Pumps :

An electrically operated End-Of-line system consists of a central pumping unit with a flow –directing valve, two main Supply Lines and suitably placed “SUR-LUB” Metering Manifolds.
The central unit is high pressure plunger type reciprocating pump driven by an electric motor. The suitably placed metering manifolds has a built in and Worm and Worm-wheel type reduction gear to obtain correct cam shaft speed. The reversing Flow Directing Valve directs the lubricant into one each of the main lines in turn , while the other line is in relief. After the pressurised line injects the lubricant to the bearings through the Metering Manifolds, pressure increases in the line to a preset valve, and operates a Pressure Control Valve located at the end of the longest branch (before the last Metering Manifold) or alternatively at the central pumping station. Operation of the Pressure Control Valve stops the Electrical Motor and activates the reversing Flow Directing Valve, so that the next cycle the lubricant many be delivered through the other main line. In this range our models include Duotrol 60/120/133/150/300/500 C.C. min.
A relay logic Control Panel is supplied together with the Pump to co-ordinate the entire electrical operation and also the resumption of successive cycles at desired intervals. The Control Panel is also designed to give Audio-Visual warning signals, in case, due to any reason, a lubricating cycle is not found to be completed within a preset stipulated period. Restarting successive cycles of lubrication may be done in any of the following ways:-

(i) Automatically at regular intervals by help of an electrical Time Clock.
(ii) Electrically inter-locked with the parent machine to make a cycle of lubrication, whenever a preselected movement of the parent machine takes place.
(iii) Whenever desired, by help of an over-riding Push Button.




Metering Manifolds :

AFMC manufactures a wide range of metering manifolds (Dose feeders) which include product equivalents of various world renowned manufacturers. We manufacture product equivalents of Lincoln , Delimon, Daikin, IHI, Samsung, Farval USA, Farval, UK etc. All the Models we manufacture vary in dimensions, inlet & outlet threads and discharge which make them equivalent to their counterparts and also provides a wide variety of combinations which suit the client’s exact requirements.

Single-Outlet Series:

"AFMC" metering manifolds are used as positive metering devices in Two-Line lubrication systems.The metered injection of lubricant at high pressure is achieved by means of ingenuous valvepiston combination.Discharge from each outlet can be individually adjusted by means of screws located at the top of the indicator housing.Indicator stems attached to pistons give positive visual indication of operation .Special seals prevent leakage past indicator stems.

Max Working Pressure – 400 bar.

S.No. Model No. No. of Outlets Discharge/Stroke/Outlet (c.c.)
01. MM series 2 - 8 0.5 – 25 c.c.
02. DM series 1 - 4 0.20 – 28.5 c.c.
 
^TOP
<PRODUCTS INDEX

Double Outlet Series

'AFMC' Two-line metering manifolds provide an economic means for positive metering of lubrications into bearings.The ingenuous pistonvalve combination in this series is so constructed that each piston is capable of lubricating two bearings in two consecutive lubrication cycles. Discharge from each piston can be adjusted by means of adjusting screws located at the top of each indicator housing. Floating indicator stems attached to each piston gives positive indication of operation. Special seals prevent leakage past indicator stems.

Max Working Pressure – 400 bar.

S. No. Model No. No. of Outlets Discharge/Stroke/Outlet  (c.c.) Equivalent to
01. DMJ series 2 - 8 0.00 – 0.65 c.c. Standard
02. DMM series 2 - 8 0.5 – 25.0 c.c. Standard
03. DMU series 2 - 8 0.0 – 5.0 c.c. Standard
04. DMX series 2 - 8 0.20 – 1.20 c.c. Farval USA & UK / Daikin
05. DMY series 2 - 8 0.50 – 2.25 c.c. Farval / Daikin/Lincoln
06. DMA series 2 - 8 0.50 – 3.50 c.c. Farval UK
07. DMZ series 2 - 8 1.20 – 5.10 c.c. Farval / Daikin/Lincoln
08. VSKH series 2 - 8 0.0 – 1.5 c.c. Lincoln
09. VSKV series 2 – 8 0.0 – 1.5 c.c. Lincoln
10. VTSK 2 - 6 0.0 – 8.0 c.c. Lincoln
11. DV series 1 - 4 0.2 – 14.0 c.c. Daikin
12. VSG series 2 - 8 0.5 – 2.25 c.c. Lincoln
13. DDU series 2 - 8 0.5 – 3.50 c.c. Farval UK
14. VSL series 2 - 8 1.20 – 5.10 c.c. Lincoln
15. DLM series 2 - 8 0.0 – 1.5 c.c. Delimon
16. VSN – KR series 2 - 8 0.0 – 1.15 c.c. Lincoln

 

EQUIVALENTS:
S No. Our Model No. Equivalent Models

 01.

 DMX series  Farval(USA):DD3,Farval(UK):DDE3,Daikin:DW3

 02.

 DMY series  Farval(USA):DD4,Farval(UK):DDE4,Lincoln:VSG,Daikin:DW4

 03.

 DMA series  Farval(UK):DDU

 04.

 DMZ series  Farval(USA):DD5,Farval(UK):DDE5,Lincoln:VSL,Daikin:DW5

 05.

 VSKH series  Lincoln

 06.

 VSKV series  Lincoln

 07.

 VTSK series  Lincoln

 08.

 DV series  Daikin

 09.

 DLM series  Delimon

 10.

 VSG, VSL series  Lincoln

 11.

 DDU series  Farval (UK)






^TOP